Product Information

Structural Template

Are you sure you want to delete? Login is required. Please enter a comment. Maximum number of characters exceeded. Copy completed. You do not have permission.
Anchorage Zone with Straight Tendons
Writer admin Date 2020.01.21 Hit 322
File 07.png

Dimension

The dimensions of an anchorage zone with straight tendon(s) and the information on a bearing plate are assigned. The boundary lines of the anchorage zone are drawn according to the assigned dimensions. The direction Left indicates that the forces by prestressing tendons act from left to right. The symbol T is the thickness of the zone.





Load

The jacking force is assigned. The jacking force must be positive value.




STM setting

Four reference distances A, B, C, and D are assigned for the automatic construction of the strut-tie model for the anchorage zone.





Rebar

The areas of reinforcing bars assigned to the anchorage zone with straight tendons are recognized as the steel tie areas of the strut-tie model for the anchorage zone. The information on the reinforcing bars can be altered, added, or deleted in the DEFINE-Tie Types-Reinforcement Ties. The information can be assigned to the elements of the strut-tie model in the ASSIGN-Tie Types.


Prev Deep Beam with Concentrated Loads
Next Anchorage Zone with Inclined Tendons